Advanced Settings

This section describes how to set the advanced parameters of UltraPath for Windows.

Procedure

  1. On the menu bar of the UltraPath Console, choose System > Global Settings.
    The Settings dialog box is displayed.
  2. Click the Advanced Settings tab.
  3. In the I/O Retry Settings area, set the I/O retry parameters. The following table describes the parameters:

    Parameter

    Description

    Value

    Retry Times

    I/O retry times.

    The value ranges from 0 to 60.

    [Default value]

    10

    [Example]

    10

    Retry interval (s)

    I/O retry interval.

    The value ranges from 0 to 10.

    [Default value]

    0

    [Example]

    0

  4. In the Routine Path Test Settings area, set the path routine test parameters. The following table describes the parameters:

    Parameter

    Description

    Value

    Idle path routine test interval (s)

    Routine test interval of idle paths.

    The value ranges from 1 to 2,592,000.

    [Default value]

    60

    [Example]

    60

    Faulty path routine test interval (s)

    Routine test interval of faulty paths.

    The value ranges from 1 to 2,592,000.

    [Default value]

    10

    [Example]

    10

  5. In the Performance Data Recording Settings area, set the performance data record function. The following table describes the parameters:

    Parameter

    Description

    Value

    Performance data recording

    Performance data record function.

    The value can be on or off.

    The performance data file is saved in the UltraPath log directory and is named perf_record.log.

    [Default value]

    off

    [Example]

    off

    Duration (h)

    Time during which the performance data record function works

    The value ranges from 0 to 8,760, expressed in hours. 0 indicates that the performance data record function works permanently.

    [Default value]

    0

    [Example]

    0

  6. In the HyperMetro Settings area, set the HyperMetro parameters. The following table describes the parameters:

    Parameter

    Description

    Value

    HyperMetro Mode

    HyperMetro working mode.

    The value can be either Priority or Balance.

    [Default value]

    Priority

    [Example]

    Priority

    Primary Array Sn

    The SN of the primary array.

    [Default value]

    None

    [Example]

    210235G6GRZ0B5000024

    Split Size

    Fragment size.

    The value ranges from 512 bytes to 1 GB.

    [Default value]

    128MB

    [Example]

    128MB

    load balance mode for HyperMetro

    load balance mode for HyperMetro configured across arrays.

    Its value can be split-size or round-robin.

    NOTE:
    • If split-size mode is selected, UltraPath delivers I/Os to a specific storage array based on the start addresses of I/Os, the size of slices that are set, and the preferred storage array. If the fragment size is 128 MB, the I/Os with start addresses from 0 MB to 128 MB are delivered to the preferred storage array, and the I/Os with start addresses from 128 MB to 256 MB are delivered to the non-preferred storage array.
    • If round-robin mode is selected, UltraPath delivers I/Os to two storage systems in turn.

    [Default value]

    split-size

    [Example]

    split-size

  7. In the Others area, set other advanced parameters. The following table describes the parameters:

    Parameter

    Description

    Value

    Failback latency time (s)

    Latency for path failover.

    The value ranges from 0 to 3,600.
    NOTE:
    If you set the value to 0, failback latency is closed.

    [Default value]

    60

    [Example]

    60

    I/O suspension period (s)

    I/O suspension period.

    The value ranges from 0 to 2,592,000.

    [Default value]

    60

    [Example]

    60

    Max. I/O timeout period (s)

    Maximal I/O timeout period of a LUN

    The value ranges from 1 to 2,592,000.

    [Default value]

    1800

    [Example]

    1800

  8. Click OK.

    NOTE:
    If you want to restore the default global settings, click Reset.