Advanced Settings

This section describes how to set the advanced parameters of UltraPath for Windows.

Procedure

  1. On the menu bar of the UltraPath Console, choose System > Global Settings.
    The Settings dialog box is displayed.
  2. Click the Advanced Settings tab.
  3. In the I/O Retry Settings area, set the I/O retry parameters. The following table describes the parameters:

    Parameter

    Description

    Value

    Retry Times

    I/O retry times.

    The value ranges from 0 to 60.

    [Default value]

    10

    [Example]

    10

    Retry interval (s)

    I/O retry interval.

    The value ranges from 0 to 10.

    [Default value]

    0

    [Example]

    0

  4. In the Routine Path Test Settings area, set the path routine test parameters. The following table describes the parameters:

    Parameter

    Description

    Value

    Idle path routine test interval (s)

    Routine test interval of idle paths.

    The value ranges from 1 to 2,592,000.

    [Default value]

    60

    [Example]

    60

    Faulty path routine test interval (s)

    Routine test interval of faulty paths.

    The value ranges from 1 to 2,592,000.

    [Default value]

    10

    [Example]

    10

  5. In the HyperMetro Settings area, set the HyperMetro parameters. The following table describes the parameters:

    Parameter

    Description

    Value

    HyperMetro Mode

    HyperMetro working mode.

    The value can be either Priority or Balance.

    [Default value]

    Priority

    [Example]

    Priority

    Primary Array Sn

    The SN of the primary array.

    [Default value]

    None

    [Example]

    210235G6GRZ0B5000024

    Split Size

    Fragment size.

    The value ranges from 512 bytes to 1 GB.

    [Default value]

    128MB

    [Example]

    128MB

  6. In the Others area, set other advanced parameters. The following table describes the parameters:

    Parameter

    Description

    Value

    Failback latency time (s)

    Latency for path failover.

    The value ranges from 0 to 3,600.
    NOTE:
    If you set the value to 0, failback latency is closed.

    [Default value]

    600

    [Example]

    600

    I/O suspension period (s)

    I/O suspension period.

    The value ranges from 0 to 2,592,000.

    [Default value]

    60

    [Example]

    60

    Max. I/O timeout period (s)

    Maximal I/O timeout period of a LUN

    The value ranges from 1 to 2,592,000.

    [Default value]

    1800

    [Example]

    1800

  7. Click OK.

    NOTE:
    If you want to restore the default global settings, click Reset.