Viewing Virtual LUN Information

This section describes how to view the detailed information about a virtual LUN.

Procedure

  1. In the navigation tree of the UltraPath Console, choose Host > VLUN.
  2. On the function pane, view virtual LUN information. Related parameters are explained in the following table.

    Parameter

    Description

    Value

    ID

    ID allocated by UltraPath for Windows to the virtual LUN.

    [Example]

    1

    Disk

    Name of the disk that corresponds to the virtual LUN on the operating system.

    [Example]

    Disk1

    Type

    Type of the virtual LUN.

    The value can be Common, HyperMetro, or Migration.

    [Example]

    Common

    Capacity

    Capacity of the virtual LUN.

    [Example]

    10.00 GB

    Number of Paths

    Number of logic paths of the virtual LUN.

    [Example]

    1

    LUN WWN

    WWN of the virtual LUN.

    [Example]

    60022a11000ac1bf0cb9754a0000016e

  3. In the function pane, select the virtual LUN whose information you want to view, click the LUN tab page. Details about this virtual LUN are displayed. Related parameters are explained in the following table.

    Parameter

    Description

    Value

    Name

    Name of the virtual LUN.

    NOTE:
    The name is specified when the LUN is created on its storage array.

    [Example]

    LUN_01

    Dev LUN ID

    ID of the storage system LUN corresponding to the virtual LUN.

    [Example]

    001

    Status

    Working status of the virtual LUN.

    The value can be Normal, Fault, Degraded, Disabled, or --.

    NOTE:
    If the LUN on the array is in Fault state while the virtual LUN on the host is in Normal state (viewed by using UltraPath), the virtual LUN can be accessed by the host.

    [Example]

    Normal

    Working Controller

    Working controller of the virtual LUN.

    [Example]

    0A

    Owning Controller

    Owning controller of the virtual LUN.

    [Example]

    0A

    Number of Paths

    Number of logic paths of the virtual LUN.

    [Example]

    1

    LUN WWN

    WWN of the virtual LUN.

    [Example]

    60022a11000ac1bf0cb9754a0000016e

    Disk Array ID

    ID of the storage system to which the virtual LUN belongs.

    [Example]

    0

    Disk Array Name

    Name of the storage system to which the virtual LUN belongs.

    [Example]

    SN_2004

    Array SN

    Serial No. of the storage system to which the virtual LUN belongs.

    [Example]

    201235G6EAZ0C1000025

    Vendor Name

    Manufacturer of the storage system to which the virtual LUN belongs.

    [Example]

    HUAWEI

    Product Name

    Name of the storage system to which the virtual LUN belongs.

    [Example]

    S5500T

  4. Optional: Check path information about the virtual LUN.
    1. In the upper part of the function pane, click the Path tab.
    2. On the Path tab page, view the detailed information about the virtual LUN. The following table describes related parameters:

      Parameter

      Description

      Value

      ID

      ID of the physical path.ID of the storage system to which the virtual LUN belongs.

      [Example]

      0

      Disk Array ID

      ID of the storage system to which the virtual LUN belongs.

      [Example]

      0

      Initiator Port

      Name of an initiator port.

      [Example]

      iqn.1998-01.com.vmvare:localhost-51a7d306

      Controller

      ID or Name of a controller.

      [Example]

      0A

      Target Port

      Name of a target port.

      [Example]

      iqn.2006-08.com.huawei:oceanstor:21000022a10ac1bf::129.97.50.2-1020400

      Status

      Working status of a physical path.

      The value can be Normal, Fault, BUSY Degradation, I/O discrete error degradation, Intermittent failure degradation, High latency degradation, Potential fault degradation or Disable.

      [Example]

      Normal

      Port Type

      Type of a link port.

      [Example]

      iSCSI